What are the differences between power consumption, installed power and installed capacity of the tempering furnace?

Views: 29     Author: Site Editor     Publish Time: 2020-02-14      Origin: Site

The power consumption of tempering furnace refers to the amount of power consumed by tempering a certain number of glass. Its unit is generally expressed in kilowatt hours (KWH). A certain amount of glass is determined by the area of glass placed in the tempering furnace, that is, the loading capacity, the type and thickness of glass. For example: the power consumption of a certain tempering furnace is 4 degrees, which means that the power consumption is 4 degrees when tempering 1 square meter 5 mm thick white glass.

The installed power of the tempering furnace refers to the total power of the electrical parts of the tempering furnace. The installed power has nothing to do with the power consumption of the tempering furnace. Its unit is generally expressed in kilowatts (kw). For example, the power of the heating part of the tempering furnace refers to the production capacity of the furnace at full load. The installed power of tempering furnace should match the installed capacity. For example: the installed power of a2436 tempering furnace is 800KW; if the installed capacity is 800kVA, it is appropriate to equip 800kVA transformer. If the transformer is too small, it will not reach its production capacity; if the transformer is too large, it will increase costs and waste resources.

The installed capacity of tempering furnace refers to the size of transformer recommended by the manufacturer. Its unit is generally expressed in kilovolt ampere (kVA). For example, when the installed capacity of a2436 radiation tempering furnace is 800kVA and the loading capacity is 65%, the continuous production capacity of tempered 5mm white glass is 15 furnaces / hour. If we want to reduce the installed capacity of the tempering furnace, we only need to reduce the load of the furnace and reduce the production efficiency of the furnace. Therefore, in order to achieve the continuous production capacity, quality standards and power consumption of the tempering furnace, it is necessary to equip appropriate transformers to provide appropriate installed capacity.


  • 11F, Publishing Building, NO.182 Haier Road, Qingdao, Shandong, China.
  • E-MAIL US:
    info@toyocc.com
  • CALL US ON:
    +86-17667538368
 COPYRIGHTS 2023 TOYOCC ALL RIGHTS RESERVED. SITEMAP